Heating Bath Circulator

Heating Bath Circulator
Heating Bath Circulator
Heating Bath Circulator

Salient Features

HB Series (Ambient to 200°C) - Heating Bath

ModelTemperature RangeHeating kWPump Flow MaxPump Pressure MaxDimensions (W X D X H)mmEnd Connection
Amb. to +200114-16 LPM0.4 bar300 X 500 X 450M.16 Male
Amb. to +200214-16 LPM0.4 bar430 X 560 X 550M.16 Male
Amb. to +200330-35 LPM0.7 bar510 X 620 X 600M.24 Male

HTC Series (Ambient to 350°C) - High Temperature Circulator

ModelTemperature RangeHeating kWPump Flow MaxPump Pressure MaxDimensions (W X D X H)mmEnd Connection
Amb. to +350330-35 LPM0.7 bar410 X 410 X 700M.24 Male
Amb. to +350630-35 LPM0.7 bar600 X 600 X 900M.24 Male
Amb. to +3501250-55 LPM0.7 bar900 X 900 X 1100M.42 Male
Note:
  • The temperature range mentioned above is at outlet of the heating bath circulator machine hence temperature inside the process / load may vary due to various factors like process design, distance, head, insulation etc.
  • In HTC series, machines with higher heating capacity also available on request
  • In HTC series, flame proof options are available on request
  • Control panel dimensions: 300 x 300 x 300 mm

Heat Transfer Fluids for HB Series

HTF GradeWorking Temp. Range
S 50Amb. to +200°C

Heat Transfer Fluids for HTC Series

HTF GradeWorking Temp. Range
S 350Amb. to +350°C
T 55Amb. to +320°C
T 66Amb. to +350°C

Optional Accessories

Optional Accessories